QC Copper Reports 3 Wide Copper Gold Zones of In-Pit Mineralization
QC Copper Reports 3 Wide Copper Gold
Zones of In-Pit Mineralization
TORONTO
,
Aug. 24, 2022
/CNW/ - QC Copper and Gold Inc. ("
QC Copper
" or the "
Company
")
(TSXV: QCCU) (OTCQB: QCCUF) is pleased to report new assay results from its current drill
program on the Opemiska Copper-Gold Property.
Highlights of Gap Zone Results Include:
OPM-22-209
0.38% Cu and 0.38 gpt Au over 39.5m
(from 86.5m to 126m)
And
0.75% Cu and 1.34 gpt Au over 13.6m
(from 198m to 211.6m)
OPM-22-211
0.42% Cu and 0.18 gpt Au over 28.5m
(from 51m to 79.5m)
And
0.62% Cu and 0.23 gpt Au over 54.0m
(from 234m to 238m)
OPM-22-214
0.36% Cu and 0.23 gpt Au over 42.8m
(from 35.2m to 78m)
And
1.49% Cu and 1.29 gpt Au over 3.5m
(from 120m to 123.5m)
Holes 209, 211, and 214, were drilled in the Gap Zone between Vein #1 and Vein #3 and include
Vein #2. These holes intersected wide zones of copper/gold mineralization that are present as
stacked zones and each hole successfully traversed open stopes and therefore do not include the
high-grade mined-out vein material but only their lower-grade envelopes. Other unnamed veins, too
narrow for underground mining, were also encountered. As a result, much of the material reported
here was not included in Opemiska's 2021 Mineral Resource Estimate ("MRE"). The Gap Zone is in
the Starter Pit area that demonstrated higher grades and lessor strip ratio in the MRE.
Click here to view cross sections and plan view of reported intesections.
Summary of reported composite intersections: Table
1
Hole ID
UTM
Coordinates
(East/North)
From
(m)
To
(m)
Interv
al
(m)
Grade
Copper
(%)
Gold
(gpt)
Silver
(gpt)
Zinc
(ppm)
Cobalt
(ppm)
OPM-22-209
509775 /
5515040
60
73.5
13.5
0.567
0.251
2.71
50
34
OPM-22-209
86.5
126
39.5
0.378
0.38
2.37
47
33
OPM-22-209
146.2
162
15.8
0.398
0.306
5.17
631
50
OPM-22-209
198
211.6
13.6
0.747
1.336
4.64
96
51
OPM-22-209
262.5
273
10.5
0.14
0.125
0.84
72
31
OPM-22-211
509725 /
5515066
6
13
7
0.375
0.094
1.09
51
30
OPM-22-211
24
33
9
0.722
0.297
2.99
54
31
OPM-22-211
51
79.5
28.5
0.417
0.18
2.01
87
34
OPM-22-211
133.5
142.5
9
0.182
0.094
1.5
37
44
OPM-22-211
159.8
181.5
21.7
0.154
0.125
2.03
952
32
OPM-22-211
234
288
54
0.619
0.229
3.38
370
59
OPM-22-211
336
351
15
0.269
0.12
1.27
59
35
OPM-22-214*
50972 /
5515000
10.5
18
7.5
0.155
0.058
0.94
54
25
OPM-22-214
35.24
78
42.76
0.358
0.228
2.96
489
35
OPM-22-214
120
123.5
3.5
1.492
1.29
17.38
20677
68
OPM-22-214
163.5
172.5
9
0.266
0.081
1.5
103
36
*
Results pending for end of hole OPM-22-214 which was drilled to 334.5 metres.
Change in Assay Reporting Format
QC Copper will be switching its assay reporting format from copper equivalent grades individual
metal concentrations. The Company believes this format more accurately reflects the true metal
content as it avoids variable and subjective inputs like the price of metal and foreign exchange
calculations.
QP Statement
The technical information contained in this news release has been reviewed and approved by
Charles Beaudry
, P.Geo and géo., Director and Vice President Exploration for QC Copper & Gold,
a Qualified Person, as defined in "National Instrument 43-101, Standards of Disclosure for Mineral
Projects." For the exploration undertaken by QC Copper & Gold, all assay batches are
accompanied by rigorous Quality Assurance procedures that include the insertion of standards and
blanks and verification assays in a secondary laboratory. All the core received from the drill is split in
half, bagged and sent to ALS-Global facilities in Quevillon,
Quebec
for sample preparation and then
the pulps are shipped to AlS-Global's
Vancouver
laboratory or some other location in the world for
analysis using ALS-Global's standardized ISO-compliant methods, all of which are listed in the
laboratory certificates provided with the assay results. The remaining half core along with the
rejects and the pulps returned from the laboratory are securely stored at QC Copper's facilities in
Chapais, Quebec
. Quality Control results, including the laboratory's control samples, are evaluated
immediately on reception of batch results and corrections implemented immediately if necessary. All
drill collars are surveyed and positioned in UTM coordinates. Collars are oriented using a gyroscopic
north-finding system and downhole deviations surveys are done with a single-shot gyroscopic
instrument at 30 to
50m
intervals. For veins oriented approximately east-west and dipping towards
the north, and drill holes oriented due south and plunging between 50 and 65 dips, the true width of
mineralized intersections are equal or greater than 80% of the quoted core length composite
intervals. This observation also holds for veins oriented northwest-southeast and dipping towards
the northeast with holes drilled towards the southwest at 225 degrees with dips between 50 and 65
degrees. However for other drill hole orientations relative to these veins or other less common vein
orientations, the true widths of mineralized intersections are less.
For information and updates on QC Copper and Gold, please visit:
www.qccopper.com
And please follow us on Twitter
@qccoppergold
Neither TSX Venture Exchange nor its Regulation Services Provider (as that term is defined in the
policies of the TSX Venture Exchange) accepts responsibility for the adequacy or accuracy of this
release. Certain information in this press release may contain forward-looking statements. This
information is based on current expectations that are subject to significant risks and uncertainties
that are difficult to predict. Actual results might differ materially from results suggested in any
forward-looking statements. QC Copper and Gold Inc. assumes no obligation to update the
forward-looking statements, or to update the reasons why actual results could differ from those
reflected in the forward looking-statements unless and until required by securities laws applicable
to QC Copper and Gold Inc. Additional information identifying risks and uncertainties is contained
in filings by QC Copper and Gold Inc. with Canadian securities regulators, which filings are
available under QC Copper and Gold Inc. profile at
www.sedar.com
.
SOURCE
QC Copper & Gold Inc.
View original content:
http://www.newswire.ca/en/releases/archive/August2022/24/c3995.html
%SEDAR: 00045293E
For further information:
To speak to the Company directly, please contact: Stephen Stewart,
Chief Executive Officer, Phone:
416.644.1571, Email: [email protected]
CO: QC Copper & Gold Inc.
CNW 06:00e 24-AUG-22