Saturday, September 26, 2026
MiningNewsTerminal
Saturday, September 26, 2026 Admin

VO.V ·

ValOre Reports Further Encouraging Metallurgical Testing Results from Pedra Branca PGE Project: 91% palladium recoveries in cyanide leach and 82% platinum recovered in 32% mass in gravity sort

Metallurgy & Processing

ValOre Reports Further Encouraging Metallurgical Testing Results from Pedra Branca PGE

Project: 91% palladium recoveries in cyanide leach and 82% platinum recovered in 32% mass in

gravity sort

November 9, 2020

Vancouver, B.C. ValOre Metals Corp. (“ValOre”; the “Company”; TSX ‐V: VO; OTC: KVLQF;

Frankfurt: KEQ0) today announced preliminary metallurgical results for cyanide leach and Falcon Ultra -

Fine (“UF”) testwork for ValOre’s 100%-owned Pedra Branca Platinum Group Element (“PGE”) Project in

northeastern Brazil.

“We are extremely pleased with both the high palladium recoveries achieved with cyanidation tests and the

gravity concentration tests which showed more than 80% of the platinum recovered in 32% of the mass ,”

stated ValOre’s Chairman and CEO, Jim Paterson. “These favorable and complimentary results

significantly increase the optionality related to future development of the Pedra Branca project and they

provide real impetus for ValOre to continue to perform tests to optimize conditions and improve metallurgical

recoveries.”

Highlights from Cyanide Leach and Falcon UF Gravity Tests at Pedra Branca

• Hot cyanide metallurgical test recoveries of 84.4%, 88.5 % and 91.7% palladium (“Pd”) were

achieved;

• Falcon UF gravity test work was very effective at concentrating platinum (“Pt”) with 73.3% Pt

recovered in only 9.6% of the mass and 82.6% Pt recovered in 32.1% of the mass;

• Falcon UF gravity concentration may serve to optimize conditions required for the Platsol™ process

(see news release date November 2, 2020) by favorably rejecting acid-consuming minerals, and

consequently, three subsequent Platsol™ optimization tests have been initiated.

PGE Cyanidation Testwork

Palladium and platinum are readily soluble in a cyanide leach solution under certain chemical conditions.

To assess the potential of cyanide leaching as a means to recover PGEs at Pedra Branca, three initial 48-

hour hot cyanide leach tests were conducted at SGS Lakefield, Ontario (“SGS”) . These tests were

conducted on : 1) composite drill core sample from the Curiu 2PGE+Au deposit (100,000oz at 1.93 g

2PGE+Au/t); 2) an outcrop sample from the Trapia 2PGE+Au deposit (219,000oz at 1.19 g 2PGE+Au/t) ;

and 3) tailings material collected from the first Falcon UF Gravity Concentrator test (see “Falcon UF Gravity

Separation” below) . Recoveries of 84.4 %, 88.5 % and 91.7% Pd were achieved in 48 -hour leach

experiments. See Table 1 below for a summary of cyanidation results, and Table 2 below for a description

of sample details.

The hot cyanide leach tests were performed with the following conditions:

• Grind size = 20-30 μm (P80)

• Pulp density = 33% solids (w/w)

• Pulp temperature = 50°C

• Cyanide concentration = 20 g/L NaCN (maintained)

• Dissolved Oxygen = 20 mg/L (maintained)

• Retention time = 48 hours

• Kinetic solution subsamples assayed for Pt and Pd after ~6, 24 and 48 hours

Table 1: Summary of Hot Cyanide Leach Results

Sample Tailing

from Test

% Extraction

Platinum Palladium

6 h 24 h 48 h 6 h 24 h 48 h

Curiu Core -- 1 2 2.6 81 88 91.7

Trapia West Outcrop -- 2 3 4.2 47 74 84.4

Curiu Core G1 5 5 7.2 83 90 88.5

Table 2: Description of Sample Details

Sample Type Source Weight

Received

Pd

(g/t)

Pt

(g/t)

Rh

(g/t)

Au

(g/t)

3PGE+Au

(g/t)

Historical Drill

Core

Curiu Deposit

20-25 kg 3.83 6.86 0.25 0.24 11.2

Outcrop Curiu Deposit

20-25 kg 7.86 3.95 0.45 0.30 12.6

Outcrop Trapia West

Deposit 20-25 kg 21.6 17.0 0.25 0.83 39.6

The strong leachability of Pd in all three tests warrants subsequent cyanidation tests aimed at improving

the performance of Pt recoveries. The addition of chloride and/or iodine as an additive in future testing may

promote reaction activity and this could positively impact the recoveries of both Pt and Pd.

About Cyanidation of PGEs

Further information about cyanide leaching can be found in the link below:

https://www.sgs.ca/en/mining/metallurgy-and-process-design/cyanidation-technologies/cyanide-leaching

Falcon UF Gravity Separation

Previous mineralogical studies of Pedra Branca mineralized ultramafic rocks suggest a very fine nature to

the PGE minerals (<9 micrometer (“μm”)) and thus multiple rounds of testwork have been initiated to assess

the potential to upgrade feed material by means of a fine grind (-20 to -38 μm) followed by gravity separation

using the Falcon UF Gravity Concentrator. The primary objective is to scavenge ultra-fine mineral particles

that are typically rejected from conventional gravity processing circuits as slimes.

The first round of Falcon UF testwork (“G1”) was completed on a sample of historical drill core from the

Curiu 2PGE+Au deposit (NI 43 -101 resource of 100,000oz 2PGE+Au at 1.93 g/t). A summary of the

samples tested is included in Table 2 above. Platinum responded very favorably to Falcon UF Gravity

concentration, with 73.3% Pt separated into only 9.6% of the mass, 82.6% Pt separated into 32.1% of the

mass, and 57.8% Pt on the first mass pull (4.6% of the mass). Palladium responded less favorably to Falcon

UF concentration, with 47.7% Pd recovered in 32.1% of the mass. See Figure 1 and Table 3 below for a

summary of G1 test results, which were run under the following test protocols: 5 kg feed at -38 μm, 10-15%

solids with ~ 3 litres/minute pulp feed rate.

• 300 G-Force centrifugal pressure

• Recover Pass 1 Concentrate and retain

• Repass Pass 1 Tailing

• Repeat for a total of 8 passes – expected mass recovery of 20-25% in total

• Filter, dry and weigh all products and submit for assay (8 concentrates, 1 tailing), including Cr, Pt

and Pd

• Metallurgical balance relating mass recovery to PGE recovery

Figure 1: Summary Graph of G1 Falcon UF Gravity Test Results

Table 3: Summary Table of G1 Falcon UF Gravity Test Results

Product Mass Assays, g/t Distribution %

g % Pt, g/t Pd, g/t Cr, % Pt Pd Cr

Pass 1 Concentrate 226.7 4.6 44.5 21.9 15.1 57.8 15.0 8.6

Pass 1+2 Concentrate 477.3 9.6 26.8 17.9 16.8 73.3 25.9 20.1

Pass 1-3 Concentrate 707.1 14.2 19.0 15.1 17.1 77.0 32.3 30.2

Pass 1-4 Concentrate 921.6 18.5 15.0 13.2 16.9 79.0 37.0 39.0

Pass 1-5 Concentrate 1121.0 22.5 12.5 11.9 16.4 80.2 40.4 46.1

Pass 1-6 Concentrate 1297.9 26.1 10.9 11.0 16.0 81.2 43.3 52.0

Pass 1-7 Concentrate 1455.6 29.2 9.8 10.3 15.6 82.0 45.5 56.9

Pass 1-8 Concentrate 1600.1 32.1 9.0 9.8 15.4 82.6 47.4 61.6

Given the strong performance of Pt concentration in the G1 test, a subsequent round of Falcon UF

concentration testwork (“G2”) was performed, aimed at further improving recoveries by a sequential coarse-

to-fine grind. G2 was designed to examine the response of coarsely ground (~100 µm P80) material to

standard gravity recovery techniques (Wilfley table), followed by fine grinding of the tailing (P80 = ~20 µm)

and processing at high G -Force with the Falcon UF test procedure. This assumes that the PGEs were

predominantly associated with chromite and that coarse chromite may concentrate somewhat efficiently

relative to the lighter matrix minerals.

0

20

40

60

80

100

0 5 10 15 20 25 30 35

Cumulative Recovery, %

Cumulative Mass Pull, %

Pt

Pd

Cr

Platinum once again responded well to the combined Wilfley + Falcon UF process, with 76.4% recovered

in 30.6% of the mass (Wilfley concentrate + Falcon pass 1 concentrate), and 86.9% recovered in 56.1% of

the mass in the combined Wilfley + 4 pass Falcon concentrate. Palladium showed a slight improvement to

G1 results, but required a higher mass pull, with recovery curves flattening at ~30% mass pull. The Wilfley

stage did not show a marked improvement on G1 results. CLICK HERE for Figure 2 and Table 4 for

summaries of the G2 test results.

The strong performance of Pt in both the G1 and G2 Falcon UF gravity tests, combined with strong

leachability of Pd seen in the three cyanidation tests presents two highly complementary processes to

concentrate and recover Pd and Pt at Pedra Branca. High -priority follow-up testwork is planned to further

optimize conditions and improve metallurgical recoveries.

About Falcon UF Gravity Separation

Further information about Falcon UF gravity separation can be found in the link below:

https://minerals.seprosystems.com/equipment/falcon-uf-gravity-concentrators/

ABOUT SGS

SGS is the world’s leading inspection, verification, testing and certification company. SGS is recognized as

the global benchmark for quality and integrity. With more than 89,000 employees, SGS operates a network

of more than 2,600 offices and laboratories around the world.

SGS fit -for-purpose solutions encompass the skills of qualified geologists, geostatistician, analytical

chemists, mineralogists, metallurgists, process engineers and mining engineers brought together to provide

accurate and timely mineral and process evaluation services across the entire mining life cycle.

Qualified Person (QP)

The technical information in this news release has been prepared in accordance with Canadian regulatory

requirements set out in NI 43 -101 and reviewed and approve d by Colin Smith, P.Geo., ValOre’s QP, who

oversees New Project Review for ValOre.

About ValOre Metals Corp.

ValOre Metals Corp. (TSX ‐V: VO) is a Canadian company with a portfolio of high ‐quality exploration

projects. ValOre’s team aims to deploy capital and knowledge on projects which benefit from substantial

prior investment by previous owners, existence of high -value mineralization on a large scale, and the

possibility of adding tangible value through exploration, process improvement, and innova tion.

In May 2019, ValOre announced the acquisition of the Pedra Branca Platinum Group Elements (PGE)

property, in Brazil, to bolster its existing Angilak uranium, Genesis/Hatchet uranium and Baffin gold projects

in Canada.

The Pedra Branca PGE Project comprises 38 exploration licenses covering a total area of 38,940 hectares

(96,223 acres) in northeastern Brazil. At Pedra Branca, 5 distinct PGE+Au deposit areas host, in aggregate,

a NI 43-101 Inferred Resource of 1,067,000 ounces 2PGE+ Au contained in 27.2 million tonnes grading

1.22 g/t 2PGE+Au (see ValOre’s July 23, 2019 news release). PGE mineralization outcrops at surface and

all of the currently known inferred resources are potentially open pittable.

Comprehensive exploration programs have demonstrated the "District Scale" potential of ValOre’s Angilak

Property in Nunavut Territory, Canada that hosts the Lac 50 Trend having a NI 43 ‐101 Inferred Resource

of 2,831,000 tonnes grading 0.69% U3O8, totaling 43.3 million pounds U 3O8. For disclosure related to the

inferred resource for the Lac 50 Trend uranium deposits, please refer to ValOre's news release of March

1, 2013.

ValOre’s team has forged strong relationships with sophisticated resource sector investors and partner

Nunavut Tunngavik Inc. (NTI) on both the Angilak and Baffin Gold Properties. ValOre was the first company

to sign a comprehensive agreement to explore for uranium on Inuit Owned Lands in Nunavut Territory and

is committed to building shareholder value while adhering to high levels of environ mental and safety

standards and proactive local community engagement.

On behalf of the Board of Directors,

"Jim Paterson"

James R. Paterson, Chairman and CEO

ValOre Metals Corp.

For further information about, ValOre Metals Corp. or this news release, pleas e visit our website at

valoremetals.com or contact Investor Relations toll free at 1.888.331.2269, at 604.646.4527, or by email at

[email protected].

ValOre Metals Corp. is a proud member of Discovery Group. For more information please visit :

discoverygroup.ca

Neither the TSX Venture Exchange nor its Regulation Services Provider (as that term is defined in the

policies of the TSX Venture Exchange) accepts responsibility for the adequacy or accuracy of this release.

This news release contains “forward -looking statements” within the meaning of applicable securities laws.

Although ValOre believes that the expectations reflected in its forward -looking statements are reasonable,

such statements have been based on factors and assumptions concerning future events that may prove to

be inaccurate. These factors and assumptions are based upon currently available information to ValOre.

Such statements are subject to known and unknown risks, uncertainties and other factors that could

influence actual results or events and cause actual results or events to differ materially from those stated,

anticipated or implied in the forward-looking statements. A number of important factors including those set

forth in other public filings could cause actual outcomes and results to differ materially from those expressed

in these forward -looking statements. Factors that could cause the actual results to differ materially from

those in forward-looking statements include the future operations of ValOre and economic factors. Readers

are cautioned to not place undue reliance on forward -looking statements. The statements in this press

release are made as of the date of this release and, except as required by applicable law, ValOre does not

undertake any obligation to publicly update or to revise any of the included forward -looking statements,

whether as a result of new information, future events or otherwise. ValOre undertakes no obligation to

comment on analyses, expectations or statements made by third parties in respect of ValOre, or its financial

or operating results or (as applicable), their securities.