Saturday, September 26, 2026
MiningNewsTerminal
Saturday, September 26, 2026 Admin

SME.V ·

Sama Resources Québec Completed a 1,494 line-km HELITEM2 Survey at the Lac Brulé Nickel-Copper Project in the Province of Québec outlining several high conductivity zones.

Corporate Updates

TSX Venture Symbol: SME

SAMA RESOURCES INC./

RESSOURCES SAMA INC.

Suite 132, 1320 Graham

Ville Mont-Royal, Québec

Canada, H3P 3C8

NR 2022-04

Sama Resources Québec Completed a 1,494 line-km HELITEM2 Survey at

the Lac Brulé Nickel-Copper Project in the Province of Québec outlining

several high conductivity zones.

Highlights:

• A 1,494 line-km HELITEM2 survey outlined several high conductivity-thickness

(CTP) zones characterised with elevated conductivity levels near the discovered

gossan and along an interpreted 10 km-long folded amphibolite unit.

• Based on these excellent results, a large exploration program is planned for

summer 2022 at the Lac Brulé and Lac Brennan properties. Exploration works will

include geological mapping and sampling, ground geophysical survey aim ed at

drilling priority targets by the fall of 2022. An existing vast network of forestry roads

and bridges will greatly facilitate access for all our exploration works.

Montréal, Quebec, March 22, 2022 – Sama Resource Inc. (“Sama” or the “Company”) (TSX-V: SME

| OTC -PK: SAMMF) is pleased to report that Sama Resources Québec Inc. (“SRQ”) a fully own ed

subsidiary of the Company has announced the completion and interpretation of a HELITEM 2

electromagnetic and magnetic helicopter geophysical survey of 1,494 line-kilometres (line-km) at the new

Lac Brulé nickel-copper property in the Province of Québec, Canada (Figure 1).

As a follow-up on the new gossan discovered in May 2021 ( see Press Release 2021-06-16)*1, SRQ

commissioned Xcalibur Multiphysics (MPH) Canada Inc . for a HELITEM 2 electromagnetic survey

supplemented by a high-sensitivity cesium magnetometer. One block of claims (390 claims) was flown

between December 5 and December 14, 2021. The survey coverage consisted of 1,374 km of traverse

lines flown with a spacing of 200 and 100 metres (“m”) and 119 km of tie lines with a 2000 m spacing.

Figures 2 to 5 show Xcalibur’s final compilation outlining several high conductivity -thickness-product

(“CTP”) areas grading 5 to 6 on the Conductivity Grade scale (Table1). Highest Conductivity Grade and

CTP, outlined by the late off-time channel/gates (Figures 2 & 5), are l ocated next to the discovered

gossan. Figure 6 shows the rooted EM response down to 600 m from surface. Detailed Interpretation

and targets modeling will be performed by M. Joel Simard, P. Geol./Geoph based in St-Donat, Quebec

province, Canada.

*1(Gossans are highly ferruginous rock which is the product of the oxidation by weathering and leaching of a sulfide body:

Elsevier Mineral Exploration 2013)

“While we are fully committed at exploring and developing our Ivorian Samapleu Ni-Cu assets with our

partner Ivanhoe Electric, Sama is demonstrating its ability at finding new highly prospective grounds

worldwide in totally virgin territories .” s aid Marc -Antoine Aud et, Ph.D, P.Geo and CEO of Sama

Resources Inc. Dr. Audet is continuing by saying “SRQ’s 100% owned Lac Brulé project is only 5 hours

driving north of Montreal, Québec Province, which greatly facilitate our upcoming explorations programs”

No historical prospecting or ground exploration had been reported from the Lac Brulé area prior to SRQ.

The past-producing Renzi nickel-copper mine is the closest mining activity with historical information

available. The Renzi mine is located 48 km east-southeast of the Lac Brulé property. The Company is

targeting possible accumulations of Ni and Cu mineralisation at Lac Brulé that could be of similar nature

to that at the Renzy mine, Voisey Bay Ni-Cu mine and at other well-known Ni-Cu deposits in Canada and

worldwide.

Geophysical HELITEM2 electromagnetic Program

The HELITEM 2 system is composed of a 40 m cable to which is attached the transmitter loop. The

receiver platform and the receiver coil are located at the centre of the 35 m diameter transmitter loop

approximately 0.1 m above the centre of the transmitter plane. The real time navigation GPS antenna is

on the tail boom of the helicopter. The barometric altimeter, radar altimeter, laser altimeter, video camera

and data recorder are all installed in the helicopter. GPS antennae are attached to the transmitter loop to

give positional information and transmitter orientation.

The survey used a 7.5 Hertz (“Hz”) one half cycle of the HELITEM2 system is made up of a square pulse

(on-time) of approximately thirty -four milliseconds in duration followed by approximately thirty -four

milliseconds of off -time before the pulse is repeated with the opposite polarity. After acquisition the

measured data are windowed into twenty-five ranges called “gates”. Gate widths increase as time after

turn-off increases because as the energy from the transmitter decays a wider sample must be taken to

get a valid average. The position of the first off -time gate is selected after examining several flights of

data and is as close to the transmitter turn off as possible. The power of the pulse causes eddy currents

in the system after the turn off and the first off -time gate cannot start until these have died away. The

earliest data has had less time to penetrate the subsurface and so contains information from the near

surface. Detailed technical information on the survey is available on Sama’s website.

Xcalibur MPH selected electromagnetic (“EM”) anomalies automatically using proprietary software from

both X and Z components using the fourth off-time gate and a threshold of 100 nT/s. These automatically

generated anomalies were then examined in profile form for each line against the X & Z EM responses,

decay information, magnetic responses, altimeter readings and flight path videos remo ving those not

considered valid and adding additional anomalies missed by the threshold. For each anomaly the

conductor type was interpreted and assigned to each anomaly. After reviewing all anomalies, the

following parameters were associated with each anomaly using the data for the fourth off-time gate and

where applicable: conductivity -thickness-product (CTP) ( Table 1), amplitude of EM response, last off -

time channel with an anomalous response, time constant, apparent depth and dip.

Table 1: Xcalibur’s MPH (proprietary) EM Anomaly characterisation (Conductor Grade and CTP)

(Fourth off-time gate and a threshold of 100 nT/s)

Figure 1: SRQ’s Lac Brulé project is located 148 km West -Northwest of Mont-Laurier and 290 km North west of

Montreal. The project area is located 5 hours driving north of Montreal. SRQ own s a second block of claims (Lac

Brennan) overlying an isolated gravity high in prolongation of the “Renzi shear zone”. The old Renzy Ni -Cu mine

operated from 1969 to 1972 selling nickel and copper concentrate to Falconbridge in Sudbury, Ontario.

Figure 2: Apparent Conductivity: late off-time channel/gates showing several distinc high conductivity (CTP) areas.

The composantes X and Z responses of the strong conductor (Conductor Grade: 5 and 6, see Table 1) located next

to the surface gossan is also shown.

Figure 3: Apparent Conductivity: early off-time channel/gates. The gossan location is shown with a star.

Figure 4: Total Magnetic Intensity for the Lac Brulé project. The interpreted trace of amphibolite units is shown.

Discovered gossan

Figure 5: EM Conductivity together with Conductor Classification defining two main sectors for follow-up: Gossan

Zone and the North Zone.

Figure 6: Differential conductivity: 600m depth slice.

2022 Exploration Program

SRQ will continue surface exploration at the Lac Brulé and Lac Brennan properties. Exploration works

will include geological mapping and sampling, ground geophysical survey aiming at drilling priority targets

by the fall of 2022. An existing vast network of forestry roads and bridges will greatly facilitate access for

all our exploration works.

Readers are invited to view the updated Corporate Presentation showing exploration progress at all our

properties : https://samaresources.com/i/pdf/Sama_Corporate_Presentation.pdf

The technical information in this release has been reviewed and approved by Dr. Marc -Antoine Audet,

Ph.D geology, P.Geo and President and CEO of Sama, and a ‘qualified person’, as defined by National

Instrument 43-101 Standards of Disclosure for Mineral Projects.

ABOUT SAMA RESOURCES INC.

Sama is a Canadian-based mineral exploration and development company with projects in West Africa

and now in Canada.

In Côte d’Ivoire only, Sama, has a strategic partnership to develop the Samapleu-Yepleu nickel-copper-

palladium project with Ivanhoe Electric (previously HPX) of which mining entrepreneur Robert Friedland

is a significant stakeholder. For more information about Sama, please visit Sama ’s website at

http://www.samaresources.com.

FOR FURTHER INFORMATION, PLEASE CONTACT:

SAMA RESOURCES INC./RESSOURCES SAMA INC.

Dr. Marc-Antoine Audet, President and CEO

Tel: (514) 726-4158

OR

Mr. Matt Johnston, Corporate Development Advisor

Tel: (604) 443-3835

Toll Free: 1 (877) 792-6688, Ext. 5

Neither the TSXV nor its Regulation Services Provider (as that term is defined in the policies of the TSXV)

accepts responsibility for the adequacy or accuracy of this release.

Forward-Looking Statements

Certain of the statements made and information contained herein are "forward -looking statements" or

“forward-looking information” within the meaning of Canadian securities legislation. Forward -looking

statements and forward-looking information such as “plan”, “evidence”, “potential”, “appears”, “seems”,

“suggest”, are subject to a variety of risks and uncertainties which could cause actual events or results

to differ from those reflected in the forward-looking statements or forward-looking information, including,

without limitation, the availability of financing for activities, risks and uncertainties relating to the

interpretation of drill results and the estimation of mineral resources and reserves, the geology, grade

and continuity of mineral deposits, th e possibility that future exploration, development or mining results

will not be consistent with the Company's expectations, metal price fluctuations, environmental and

regulatory requirements, availability of permits, escalating costs of remediation and mitigation, risk of title

loss, the effects of accidents, equipment breakdowns, labour disputes or other unanticipated difficulties

with or interruptions in exploration or development, the potential for delays in exploration or development

activities, the inherent uncertainty of cost estimates and the potential for unexpected costs and expenses,

commodity price fluctuations, currency fluctuations, expectations and beliefs of management and other

risks and uncertainties.

In addition, forward -looking stateme nts and forward -looking information are based on various

assumptions. Should one or more of these risks and uncertainties materialize, or should underlying

assumptions prove incorrect, actual results may vary materially from those described in forward-looking

information or forward-looking statements. Accordingly, readers are advised not to place undue reliance

on forward -looking statements or forward -looking information. Except as required under applicable

securities legislation, the Company undertakes no obligation to publicly update or revise forward-looking

statements or forward -looking information, whether as a result of new information, future events or

otherwise.