Saturday, September 26, 2026
MiningNewsTerminal
Saturday, September 26, 2026 Admin

FL.V ·

Frontier Drills 322 Meters of 1.6% Li2O from Phase X Drilling at Spark

Drill Results

FRONTIER DRILLS 322 METERS OF 1.6% Li2O

FROM PHASE X DRILLING AT SPARK

SUDBURY, ON

,

Feb. 1, 2022

/CNW/ - Frontier Lithium Inc. (TSXV: FL) (OTCQX: LITOF) ("Frontier"

or "the Company") is pleased to announce the results from two of five drill holes drilled during The

Phase X drill program on the Spark pegmatite. The Spark pegmatite is one of the two delineated

premium spodumene-bearing lithium deposits on the PAK Lithium Project.

Frontier Lithium, Spark Pegmatite drill core. (CNW Group/Frontier Lithium Inc.)

Highlights

Hole PL-053-19, collared in pegmatite intersected predominately pegmatite from surface

to

329.4m

with

322.5m

averaging 1.6% Li

2

O;

Includes

80.5m

from 11.5 to

92m

and

26m

from 270 to

296m

averaging just over 2%

Li

2

O;

The lithium-rich zone represents a 200-horizontal width.

Geomechanical Drill Hole ("DDH") PL-GDH-08-21 collared in pegmatite, and intersected

94.5 m

(1 to

95.5 m

) of pegmatite averaging 1.7% Li

2

O;

Includes

14m

(13 to

27m

) averaging 2.8% Li

2

O and 498 ppm Ta

2

O

5

Includes

10m

(184 to

194m

) averaging 0.94 Li

2

O, 244 ppm Ta2O5 and 0.55% Rb2O

Includes a

3m

Ta-enriched aplite zone from 178 to

181m

averaging 618 ppm Ta

2

O

5

;

The intersection represents a horizontal width of nearly

225 m

for the Spark

pegmatite assuming a WSW trend.

3 DDH results outstanding, dissemination of results expected in the coming weeks.

"Our Spark resource update is now underway as a result of the recent drilling and we are confident

that our objectives of converting Inferred to Indicated and Measured, as well as increasing the size

of the resource will be met," states

Garth Drever

, V.P. Exploration.

The objectives for the Phase X drill program in September-

October 2021

were to complete drill

targets considered vital for completing a Pre-Feasibility Study (PFS). Figure 1 is a location map

showing the project area including Frontier's land tenure, geology, and location of the three LCT

pegmatites, PAK, Bolt and Spark while Figure 2 is a plan map of the Spark pegmatite with drill hole

traces highlighting the two holes being reported. Table 1 details the mineralized intersections in holes

PL-GDH-

07-21-21

and PL-053-21 while Table 2 is a summary of all the Phase X drill holes.

Figure 1: Location map showing geology, land tenure and location of LCT pegmatites (CNW

Group/Frontier Lithium Inc.)

Figure 2: Compilation of the Spark pegmatite showing drill hole traces highlighting DDH PL-GDH-08-

21 and PL-053-21 (CNW Group/Frontier Lithium Inc.)

Table 1: Details of Mineralized Intersections

DDH

PL-GDH-08-21

Designed as both geomechanical and delineation hole to test area between Channel 33 and the pegmatite exposure 70 m to the north and the pitwall at

depth. The hole was collared in pegmatite intersecting 95m of mineralized pegmatite averaging 1.7% Li

2

O including 14m (13 to 27m) of 2.8% Li

2

O with

498 ppm Ta

2

O

5

. Intersected narrow zones (3 to 10m) from 178 to 191m with up to 1.5% Li

2

O and 618ppm Ta

2

O

5

Zone

From

(m)

To

(m)

Width

(m)

Li

2

O

(%)

Cs

2

O

(%)

Ta

2

O

5

(ppm)

Nb

2

O

5

(ppm)

SnO

2

(ppm)

Rb

2

O

(%)

Unit

Li-Ta Enriched

1.0

95.5

94.5

1.71

0.03

172

113

61

0.35

Pegmatite plus Aplite

including

1.0

51.0

50.0

2.20

0.04

239

139

62

0.38

Pegmatite (LIZ)

including

13.0

27.0

14.0

2.80

0.03

498

309

51

0.23

Pegmatite (LIZ)

Ta-Sn Enriched

177.9

180.9

3.0

0.05

0.01

618

108

616

0.08

Aplite

Li-Ta-Rb Enriched

184.2

194.2

10.0

0.94

0.03

244

77

116

0.55

Pegmatite (LIZ)

including

185.0

191.0

6.0

1.49

0.02

181

73

96

0.52

Pegmatite (LIZ)

DDH

PL-053-21

Designed to test area west of the metavolcanic intersections in holes DDH-041-19 and PL-049-21. The hole intersected predominately mineralized

pegmatite from surface to the end of hole at 330m with minor metavolcanic horizons typically less than a metre to 7m. The pegmatite intersection

(322.5m) represents a horizontal width of over 200m with an average of 1.6% Li

2

O.

Zone

From

(m)

To

(m)

Width

(m)

Li

2

O

(%)

Cs

2

O

(%)

Ta

2

O

5

(ppm)

Nb

2

O

5

(ppm)

SnO

2

(ppm)

Rb

2

O

(%)

Unit

Li Enriched

1.4

106.5

105.1

1.82

0.04

98

96

70

0.32

Aplitic Pegmatite

including

11.5

92.0

80.5

2.03

0.04

95

81

67

0.31

Aplitic Pegmatite

including

35.5

67.1

31.6

2.27

0.03

75

95

63

0.27

Pegmatite (LIZ)

Li Enriched

112.0

329.4

217.4

1.54

0.02

70

71

45

0.22

Aplitic Pegmatite

including

136.7

306.0

169.3

1.64

0.01

74

70

42

0.20

Aplitic Pegmatite

including

270.0

296.0

26.0

2.02

0.01

63

91

44

0.21

Aplite

Table 2: Summary of Drill Holes

Geomechanical

DDHNo

Date Drilled

UTM Zone 15N (NAD83)

Collar Orient

Metres Drilled

Start

End

Easting

Northing

(mASL)

Azim

Dip

Start

End

Phase X

PL-GDH-08-21

2021-09-19

2021-09-26

472,746

5,829,496

355.0

355

-60

0

220.5

Total metres drilled

220.5

Delineation

DDHNo

Date Drilled

UTM Zone 15N (NAD83)

Collar Orient

Metres Drilled

Start

End

Easting

Northing

(mASL)

Azim

Dip

Start

End

Phase X

PL-050-21

2021-09-26

2021-10-03

472,746

5,829,494

359.0

170

-70

0

431

PL-051-21

2021-10-03

2021-10-23

472,687

5,829,527

358.0

180

-60

0

346.3

PL-052-21

2021-10-23

2021-10-27

472,815

5,829,593

359.0

160

-50

0

291

PL-053-21

2021-10-27

2021-11-01

472,766

5,829,566

360.0

177

-55

0

349.5

Total metres drilled

1,417.8

The initial hole PL-GDH-08-21 was both a delineation and geomechanical hole designed to test the

extent of pegmatite from Channels 33-35 to a pegmatite outcrop

70m

to the north and to test pit-

wall stability at depth. As illustrated in Figure 2 the entire area appears to be mineralized pegmatite

(1.7% Li

2

O from 1 to

95.5 m

) extending the pegmatite-host rock contact in alignment with the

outcrop and contacts observed to the west in holes PL-038-19 at depth and PL-042-19 near

surface.

The next two holes, PL-051-21 and PL-052-21 were drilled to fill gaps between existing holes to the

west and to the east respectively. As shown in Figure 2, significant mineralized pegmatite

intersections are present in PL-051-21 with lesser zone occurring in PL-052-21. Results of these

two holes will be reported when geochemical results are received.

The last hole of Phase X, PL-053-21 was designed to test an area west of the metavolcanic

intersections in holes DDH-041-19 and PL-049-21 (Figure 2). The hole intersected predominately

mineralized pegmatite from surface to the end of hole at

330 m

with minor metavolcanic horizons

typically less than a metre to

7 m

. The pegmatite intersection (

322.5m

) represents a horizontal width

of over

200m

with an average of 1.6% Li

2

O.

Due Diligence

All scientific and technical information in this release has been reviewed and approved by

Garth Drever, P.Geo., the qualified person (QP) under the definitions established by National

Instrument 43-101. Under Frontier's QA/QC procedures, all drilling was completed by Chenier

Drilling Ltd. of

Val Caron, ON

using thin walled BTW drill rods (4.2 cm core diameter) and a Reflex

ACT III oriented core system. Using the Reflex system, the drill core was oriented and marked as it

was retrieved at the drill. The core was boxed and delivered to the Frontier core shack where it was

examined, geologically logged, and marked for sampling. The core was photographed prior to

sampling. Using a rock saw, the marked sample intervals were halved with one half bagged for

analysis. Sample blanks along with lithium, rubidium and cesium certified reference material was

routinely inserted into the sample stream in accordance with industry recommended practices. Field

duplicate samples were also taken in accordance with industry recommended practices. The

samples were placed in poly sample bags and transported to

Red Lake

by Frontier employees and

then shipped to AGAT Laboratories Ltd. (AGAT) in

Mississauga, Ontario

for processing and

quantitative multi-element analysis. AGAT is an ISO accredited laboratory. The core is stored on

site at the Pakeagama Lake exploration camp.

About Frontier Lithium

Frontier Lithium is a preproduction business that is targeting to become a manufacturer of battery-

quality lithium materials to support electric vehicle and battery supply chains in

North America

.

Frontier owns the PAK Lithium Project which contains one of

North America's

highest-grade, large-

tonnage hard-rock lithium resources in the form of a rare low-iron spodumene. The project continues

to have significant exploration upside with potential to increase the lithium resource. The Company is

a pure-play lithium development opportunity with the largest land position in the Electric Avenue, a

premium lithium mineral district located in

Northern Ontario

.

About PAK Lithium Project

The PAK Lithium Project contains a tier one lithium resource in

North America

and is one of the

global top three premium resources by quality. A 2021 preliminary economic assessment (National

Instrument 43-101 technical report titled "Pak Property" by BBA Engineering Ltd., issued on

April 5,

2021

) delivered a fully integrated lithium operation from the resource to achieve downstream

conversion plan for production of battery-quality lithium salts. The study resulted in an after-tax net

present value (discounted at 8 per cent) of

$974-million

(U.S.) with a 21-per-cent internal rate of

return. The Project encompasses 26,774 hectares at the south end of

Ontario's

Electric Avenue, the

largest land package hosting premium lithium-bearing pegmatites in

Ontario

. The Project is

supported by a measured and indicated resource of 10.49 million tonnes (Mt) averaging 1.78 per

cent lithium oxide (Li

2

O) and inferred resource of 18.48 Mt averaging 1.45 per cent Li

2

O.The Project

covers 65 kilometres of the Electric Avenue's length and remains largely unexplored; however, since

2013, the company has delineated two premium spodumene-bearing lithium deposits (PAK and

Spark), located 2.3 kilometres apart. Considerable exploration upside is supported on the PAK

Lithium Project through two other spodumene-bearing discoveries: the Bolt pegmatite (located

between the PAK and Spark deposits), as well as the Pennock pegmatite (30 kilometres northwest

of PAK Deposit within the project claims).

Forward-looking Statements

Neither the TSX Venture Exchange nor its Regulation Services Provider (as that term is defined in

the policies of the TSX Venture Exchange) accepts responsibility for the adequacy or accuracy of

this release. This release includes certain statements that may be deemed "forward-looking

statements". All statements in this release, other than statements of historical facts, that address

future production, reserve potential, exploration drilling, exploitation activities and events or

developments that the Company expects are forward-looking statements. Although the Company

believes the expectations expressed in such forward-looking statements are based on reasonable

assumptions, such statements are not guarantees of future performance and actual results or

developments may differ materially from those in the forward-looking statements. Factors that could

cause actual results to differ materially from those in forward looking statements include market

prices, exploitation and exploration successes, continued availability of capital and financing, and

general economic, market or business conditions. Investors are cautioned that any such statements

are not guarantees of future performance and those actual results or developments may differ

materially from those projected in the forward-looking statements. For more information on the

Company, Investors should review the Company's registered filings available at

sedar.com

.

SOURCE

Frontier Lithium Inc.

View original content to download multimedia:

http://www.newswire.ca/en/releases/archive/February2022/01/c3712.html

%SEDAR: 00008434E

For further information:

Company Contact Information: Bora Ugurgel, Manager, Investor

Relations, 2736 Belisle Drive Val Caron, ON. P3N 1B3 CANADA, T. +001 705.897.7622, F. +001

705.897.7618

CO: Frontier Lithium Inc.

CNW 08:00e 01-FEB-22